M5315C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Note: Must be used with a 3A external AC fuse. |
|
M7052A ROHS
|
|
- Sec. V: 6+6
- Sec. Parallel: 0.83A
- Sec. Series: 0.41A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: ˜20%
- Weight: ˜175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M1020 ROHS
|
|
|
|
Impedance: 600 Ohm line, 600 Ohm equip.
Turns Ratio: 1:1
Max Level: 0dBm
Insertion Loss: 1.4dB max @ 1kHz
Return Loss: >16dB @ 300Hz - 3.5kHz
Proof Test: 3.0kV AC 1 minute
Dimension: 12L x 11H x 11W
Weight: 5 gms
PCB hole size: 0.7mm |
|
M7058A ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 0.55A
- Sec. Series: 0.27A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7258 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 10VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 250g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 9 + 9
- Parallel : 1.1A
- Series: 0.55A
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7158 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 7VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 265g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 9 + 9
- Parallel : 0.77A
- Series: 0.38A
- Standard AS/NZS 61558.2.6 Certified
|
|
Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M4618A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M5009C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. |
|
M2165C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 60VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜1.4kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
|
|
Powertran EI-Core 240V AC mains transformer with 6.6A dual multi tapped secondary configuration. Two sets of 0V, 9V and 12V secondaries are available at a maximum current of 6.6A (max current when 9V secondaries connected in parallel) . Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for A |
|
M5018C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. 18+18V. |
|
M5109 |
|
- Primary voltage: 240V AC
- Secondary voltage: 9V (parallel), 18V (series)
- Secondary current: 8.8A(parallel) 4.4A (series)
- Regulation: Better than 10%
- Maximum temperature rise: 75°C
- Dielectric strength: 4000V for 1 Minute
- Insulation class: Class B (130ºC)
- Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available.
- Minimum order quantity applies.
|
|
Certificate No.: CS 815/Q |
|
M7030A ROHS
|
|
- Sec. V: 15+15
- Sec. Parallel: 0.2A
- Sec. Series: 0.10A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 3VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Regulation: ˜23%
- Weight: ˜95g
- PCB hole size: 0.8mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7070A ROHS
|
|
- Sec. V: 15+15
- Sec. Parallel: 0.333A
- Sec. Series: 0.16A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7015A ROHS
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 0.4A
- Sec. Series: 0.20A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 3VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Regulation: ˜23%
- Weight: ˜95g
- PCB hole size: 0.8mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M5109C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 9V secondaries. 80VA rated.
|
|
M7112A ROHS
|
|
- Sec. V: 6+6
- Sec. Parallel: 1.166A
- Sec. Series: 0.58A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: 11%
- Weight: 265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7252 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 10VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 250g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 6 + 6
- Parallel : 1.66A
- Series: 0.83A
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7118A ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 0.77A
- Sec. Series: 0.38A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜11%
- Weight: ˜265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7255 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 10VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 250g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 7.5 + 7.5
- Parallel : 1.33A
- Series: 0.66A
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7164 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 7VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 265g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 12 + 12
- Parallel : 0.58A
- Series: 0.29A
- Standard AS/NZS 61558.2.6 Certified
|
|
Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M2156C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 30VA
- Insulation: Class E (120°C)
- Magnetising current: <65mA
- Temperature rise: <60°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜1kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
|
|
Powertran EI-Core 240V AC mains transformer with 2A multi tapped secondary configuration. 0V, 6V, 9V, 12V and 15V secondaries are available at 2A current output. Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for AS/NZS 61558.2.6. |
|
M7152 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 7VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 265g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 6 + 6
- Parallel : 1.166A
- Series: 0.58A
- Standard AS/NZS 61558.2.6 Certified
|
|
Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M2158C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 72VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜1.4kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
|
|
Powertran EI-Core 240V AC mains transformer with 3A single tap secondary configuration. 24V secondary voltage available at 3A current output. Primary and secondaries fitted with 200mm flyleads. Fully electrical authority approved for AS/NZS 61558.2.6. |
|
M7130A ROHS
|
|
- Sec. V: 15+15
- Sec. Parallel: 0.466A
- Sec. Series: 0.233A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: 11%
- Weight: 265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7055A ROHS
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 0.66A
- Sec. Series: 0.33A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |