M4324A |
|
- Sec. V: 12+12
- Sec. Parallel: 0.82A
- Sec. Series: 0.41A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4312A |
|
- Sec. V: 6+6
- Sec. Parallel: 1.67A
- Sec. Series: 0.83A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
6+6V 10VA Potted Toroidal Transformer. |
|
M4315A NEW
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 1.3A
- Sec. Series: 0.66A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M5012C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. |
|
M5025C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
|
M5015C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
|
M5009C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. |
|
M5018C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. 18+18V. |
|
M2190L |
|
- Primary voltage: 240V AC
- Total VA rating: 120VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜2.2kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042094
- AS3108 approval: CS/990/Q
|
|
Primary fitted with 200mm fly leads. Secondary taps have solder tags. |
|
M5345A |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 45V secondaries. 160VA rated.
|
|
M5109C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 9V secondaries. 80VA rated.
|
|
M5115C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 15V secondaries. 80VA rated.
|
|
M5112C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Certificate No.: CS 815/Q |
|
M5118C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 18V secondaries. 80VA rated.
|
|
M5125C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 25V secondaries. 80VA rated.
|
|
M2190C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 120VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ≈10%
- Recommended primary AC fuse: 500mA
- Weight: ≈1.4kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
|
|
Powertran EI-Core 240V AC mains transformer with 5A single tap secondary configuration. |
|
M4624A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4618A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4630A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for ideal for high performance, low noise circuits. |
|
M5545 |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
- Energy authority certified
|
|
Certificate No.: CS 815/Q |
|
M5312C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Note: Must be used with a 3A external AC fuse. |
|
M5315C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Note: Must be used with a 3A external AC fuse. |
|
M5318C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
18+18V 160VA toroidal transformer. |
|
M5325C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 25V secondaries. 160VA rated.
|
|
MA5417 |
|
|
|