Description |
Downloads |
Specs |
Ordering |
|
|
M7158 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 7VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 265g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 9 + 9
- Parallel : 0.77A
- Series: 0.38A
- Standard AS/NZS 61558.2.6 Certified
|
|
Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7155 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 7VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 265g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 7.5 + 7.5
- Parallel : 0.933A
- Series: 0.46A
- Standard AS/NZS 61558.2.6 Certified
|
|
Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7152 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 7VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 265g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 6 + 6
- Parallel : 1.166A
- Series: 0.58A
- Standard AS/NZS 61558.2.6 Certified
|
|
Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M0440 |
|
- Primary Taps:
0V, 4.2V, 9.7V, 16.2V,
32.5V, 51.2V, 100V.
- Frequency Response:
70Hz - 18kHz
|
|
Used with 100v or 70V line PA systems. This enables the user to tap from the line the required level. Taps are spaced in 4.5db steps. Power rating 40 watts RMS. |
|
M1112 |
|
- Frequency Response: 30Hz - 20kHz ±3dB
- Secondary Tap: 8 Ohm
- Power taps: 0.33W, 0.66W, 1.25W, 2.5W, 5W
|
|
5 Watt 100V line speaker transformers with tapped primary, and secondary to suit 8 Ohm speakers. |
|
M7252 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 10VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 250g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 6 + 6
- Parallel : 1.66A
- Series: 0.83A
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M1005 ROHS
|
|
|
|
Impedance: 600 Ohm line, 600 Ohm or 150 Ohm equip.
Turns Ratio: 1:1
Max Level: +20dBm @ 200Hz
Insertion Loss: 1dB max @ 0dBm
Frequency Response: 200Hz - 3KHz
Return Loss: >15dB, 200Hz - 3kHz
Max Unbalanced DC: 5mA
Proof Test: 3.5kV RMS
Dimension: 26L x 21H x 19W
Weight: 25 gms
PCB hole size: 1.3mm |
|
M2853C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 6.3VA
- Insulation: Class E (120°C)
- Magnetising current: <45mA
- Temperature rise: <65°C
- Regulation: ˜13%
- Recommended AC fuse: 100mA
- Weight: ˜315g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M7130A ROHS
|
|
- Sec. V: 15+15
- Sec. Parallel: 0.466A
- Sec. Series: 0.233A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: 11%
- Weight: 265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7124A ROHS
|
|
- Sec. V: 12+12
- Sec. Parallel: 0.58A
- Sec. Series: 0.29A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: 11%
- Weight: 265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7118A ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 0.77A
- Sec. Series: 0.38A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜11%
- Weight: ˜265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7115A ROHS
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 0.933A
- Sec. Series: 0.46A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜11%
- Weight: ˜265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7112A ROHS
|
|
- Sec. V: 6+6
- Sec. Parallel: 1.166A
- Sec. Series: 0.58A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: 11%
- Weight: 265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M4318 ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 1.1A
- Sec. Series: 0.5A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4315 |
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 1.3A
- Sec. Series: 0.66A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4312 |
|
- Sec. V: 6+6
- Sec. Parallel: 1.67A
- Sec. Series: 0.83A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M1010 ROHS
|
|
|
|
Impedance: 600 Ohm line, 600 Ohm or 150 Ohm equip.
urns Ratio: 1:1
Max Level: +20dBm @ 200Hz
Insertion Loss: 1.8dB max @ 0dBm
Frequency Response: 300Hz - 3kHz
Return Loss: >15dB, 300Hz - 3kHz
Max Unbalanced DC: 80mA
Proof Test: 3.5kV RMS
Dimension: 35L x 17H x 29W
Weight: 50 gms
PCB hole size: 1.2mm |
|
M1000 ROHS
|
|
|
|
Impedance: 600 Ohm line, 600 Ohm equip
Turns Ratio: 1:1
Max Level: 0dBm @ 300Hz
Insertion Loss: 1dB max @ 0dBm
Frequency Response: 300Hz - 10kHz
Return Loss: >15dB, 300Hz - 5kHz
Max Unbalanced DC: 60mA
Proof Test: 3.5kV RMS
Dimension: 41L x 30H x 33W
Weight: 153 gms
PCB hole size: 1.5mm |
|
M7070A ROHS
|
|
- Sec. V: 15+15
- Sec. Parallel: 0.333A
- Sec. Series: 0.16A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7064A ROHS
|
|
- Sec. V: 12+12
- Sec. Parallel: 0.416A
- Sec. Series: 0.208A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7058A ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 0.55A
- Sec. Series: 0.27A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7055A ROHS
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 0.66A
- Sec. Series: 0.33A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7052A ROHS
|
|
- Sec. V: 6+6
- Sec. Parallel: 0.83A
- Sec. Series: 0.41A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: ˜20%
- Weight: ˜175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M2854L |
|
- Primary voltage: 240V AC
- Total VA rating: 3.6VA
- Insulation: Class E (120°C)
- Magnetising current: <40mA
- Temperature rise: <65°C
- Regulation: ˜12%
- AC fuse: Not required (fitted internally)
- Weight: ˜235g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 12V, 24 / Current : 150mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2853L |
|
- Primary voltage: 240V AC
- Total VA rating: 6.3VA
- Insulation: Class E (120°C)
- Magnetising current: <45mA
- Temperature rise: <65°C
- Regulation: ˜13%
- Recommended AC fuse: 100mA
- Weight: ˜315g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
|
|
Primary and secondary fitted with 200mm fly leads. |