- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 25V secondaries. 80VA rated.
|
|
M5025A |
|
- Primary voltage: 240V AC
- Secondary voltage: 25V (parallel), 50V (series)
- Secondary current: 2A (parallel), 1A (series)
- Regulation: Better than 10%
- Maximum temperature rise: 75°C
- Dielectric strength: 4000V for 1 Minute
- Insulation class: Class B (130ºC)
- Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available.
- Minimum order quantity applies.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
|
M5025C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
|
M5530C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 30V secondaries. 300VA rated.
|
|
M5730C |
|
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Toroidal transformers are becoming increasingly popular due to their improved magnetic properties and also that they can be made to a lower profile than a standard solenoid core transformer, allowing for equipment of similar power to be of a lower profile such as rack mounted devices. |
|
M5535C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 35V secondaries. 300VA rated.
|
|
M5345A |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 45V secondaries. 160VA rated.
|
|
M5545 |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
- Energy authority certified
|
|
Certificate No.: CS 815/Q |
|
M4312 |
|
- Sec. V: 6+6
- Sec. Parallel: 1.67A
- Sec. Series: 0.83A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4312A |
|
- Sec. V: 6+6
- Sec. Parallel: 1.67A
- Sec. Series: 0.83A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
6+6V 10VA Potted Toroidal Transformer. |
|
M4315 |
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 1.3A
- Sec. Series: 0.66A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4315A NEW
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 1.3A
- Sec. Series: 0.66A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4615 |
|
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M5009C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. |
|
M5109C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 9V secondaries. 80VA rated.
|
|
M4618A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M5109 |
|
- Primary voltage: 240V AC
- Secondary voltage: 9V (parallel), 18V (series)
- Secondary current: 8.8A(parallel) 4.4A (series)
- Regulation: Better than 10%
- Maximum temperature rise: 75°C
- Dielectric strength: 4000V for 1 Minute
- Insulation class: Class B (130ºC)
- Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available.
- Minimum order quantity applies.
|
|
Certificate No.: CS 815/Q |
|
M4318 ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 1.1A
- Sec. Series: 0.5A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |