Description |
Downloads |
Specs |
Ordering |
|
|
M7118A ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 0.77A
- Sec. Series: 0.38A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜11%
- Weight: ˜265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7115A ROHS
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 0.933A
- Sec. Series: 0.46A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜11%
- Weight: ˜265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7112A ROHS
|
|
- Sec. V: 6+6
- Sec. Parallel: 1.166A
- Sec. Series: 0.58A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: 11%
- Weight: 265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7070A ROHS
|
|
- Sec. V: 15+15
- Sec. Parallel: 0.333A
- Sec. Series: 0.16A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7064A ROHS
|
|
- Sec. V: 12+12
- Sec. Parallel: 0.416A
- Sec. Series: 0.208A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7058A ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 0.55A
- Sec. Series: 0.27A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7055A ROHS
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 0.66A
- Sec. Series: 0.33A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: 20%
- Weight: 175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7052A ROHS
|
|
- Sec. V: 6+6
- Sec. Parallel: 0.83A
- Sec. Series: 0.41A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 5VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: ˜20%
- Weight: ˜175g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7030A ROHS
|
|
- Sec. V: 15+15
- Sec. Parallel: 0.2A
- Sec. Series: 0.10A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 3VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Regulation: ˜23%
- Weight: ˜95g
- PCB hole size: 0.8mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7024A ROHS
|
|
- Sec. V: 12+12
- Sec. Parallel: 0.25A
- Sec. Series: 0.125A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 3VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Regulation: 23%
- Weight: 95g
- PCB hole size: 0.8mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7018A ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 0.33A
- Sec. Series: 0.16A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 3VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Regulation: ˜23%
- Weight: ˜95g
- PCB hole size: 0.8mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7015A ROHS
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 0.4A
- Sec. Series: 0.20A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 3VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Regulation: ˜23%
- Weight: ˜95g
- PCB hole size: 0.8mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7012A ROHS
|
|
- Sec. V: 6+6
- Sec. Parallel: 0.5A
- Sec. Series: 0.25A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 3VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Regulation: ˜23%
- Weight: ˜95g
- PCB hole size: 0.8mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M2854L |
|
- Primary voltage: 240V AC
- Total VA rating: 3.6VA
- Insulation: Class E (120°C)
- Magnetising current: <40mA
- Temperature rise: <65°C
- Regulation: ˜12%
- AC fuse: Not required (fitted internally)
- Weight: ˜235g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 12V, 24 / Current : 150mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2853L |
|
- Primary voltage: 240V AC
- Total VA rating: 6.3VA
- Insulation: Class E (120°C)
- Magnetising current: <45mA
- Temperature rise: <65°C
- Regulation: ˜13%
- Recommended AC fuse: 100mA
- Weight: ˜315g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2852L |
|
- Primary voltage: 240V AC
- Total VA rating: 3.78VA
- Insulation: Class E (120°C)
- Magnetising current: <40mA
- Temperature rise: <65°C
- Regulation: ˜12%
- AC fuse: Not required (fitted internally)
- Weight: ˜235g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2190L |
|
- Primary voltage: 240V AC
- Total VA rating: 120VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜2.2kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042094
- AS3108 approval: CS/990/Q
|
|
Primary fitted with 200mm fly leads. Secondary taps have solder tags. |
|
M2170L |
|
- Primary Voltage: 240V AC
- Total VA Rating: 100VA
- Insulation: Class E (120°C)
- Magnetising Current: <85mA
- Temperature Rise: <70°C
- Regulation: ˜14%
- Recommended primary AC Fuse: 500mA
- Weight: ˜1.6kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
|
|
Powertran EI-Core 240V AC mains transformer with 6A dual multi tapped secondary configuration. Two sets of 0V, 12V and 15V secondaries are available at a maximum current of 6A (max current when secondaries connected in parallel) . Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for AS/NZS |
|
M2155L |
|
- Primary voltage: 240V AC
- Total VA rating: 15VA
- Insulation: Class E (120°C)
- Magnetising current: <60mA
- Temperature rise: <60°C
- Regulation: ˜10%
- Recommended primary AC fuse: 250mA
- Weight: ˜555g
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
|
|
Primary fitted with 200mm fly leads. Secondary taps have solder tags. |