|
Description |
Downloads |
Specs |
Ordering |
|
|
M4312 |
|
- Sec. V: 6+6
- Sec. Parallel: 1.67A
- Sec. Series: 0.83A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4312A |
|
- Sec. V: 6+6
- Sec. Parallel: 1.67A
- Sec. Series: 0.83A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
6+6V 10VA Potted Toroidal Transformer. |
|
M4315 |
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 1.3A
- Sec. Series: 0.66A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4315A |
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 1.3A
- Sec. Series: 0.66A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4318 ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 1.1A
- Sec. Series: 0.5A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4324A |
|
- Sec. V: 12+12
- Sec. Parallel: 0.82A
- Sec. Series: 0.41A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4330A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <85°C
- External AC fuse (required): 100mA
- Thermal fuse: 84°C
- Regulation: ≈20%
- Weight: ≈210g
- PCB hole size: 2mm
- Approval: SAA151379EA
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4615 |
|
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4618A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4624A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
|
M4630A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for ideal for high performance, low noise circuits. |
|
M4909B |
|
- Primary voltage: 240V AC
- Secondary voltage: 9V (parallel), 18V (series)
- Secondary current: 3.3A (parallel), 1.6A (series)
- Regulation: Better than 10%
- Maximum temperature rise: 75°C
- Dielectric strength: 4000V for 1 Minute
- Insulation class: Class B (130ºC)
- Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available.
- Minimum order quantity applies.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
|
M4909C |
|
- Low profile design is suitable for use inside our 1RU 19” rack enclosures.
- 30VA series models have potted epoxy centre core for easy mounting.
- Lower electrically induced noise demanded by compact equipment.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
|
M4912C |
|
- Supplied with 1 rubber washer, bolt and nut.
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
|
M4915C |
|
- Supplied with 1 rubber washer, bolt and nut.
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 30VA transformers will fit inside our 1 Unit 19" rack cases. |
|
M4918C |
|
- Supplied with 1 rubber washer, bolt and nut.
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
|
M4925C |
|
- Supplied with 1 rubber washer, bolt and nut.
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 30VA transformers will fit inside our 1 Unit 19" rack cases.
|
|
M5009C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. |
|
M5012C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. |
|
M5015C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
|
M5018C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. 18+18V. |
|
M5025C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
|
M5109C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 9V secondaries. 80VA rated.
|
|
M5112C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Certificate No.: CS 815/Q |
|
M5115C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 15V secondaries. 80VA rated.
|