Description |
Downloads |
Specs |
Ordering |
|
|
M4312A |
|
- Sec. V: 6+6
- Sec. Parallel: 1.67A
- Sec. Series: 0.83A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
6+6V 10VA Potted Toroidal Transformer. |
|
M6672C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 30VA
- Insulation: Class E (120°C)
- Magnetising current: <80mA
- Temperature rise: <65°C
- Regulation: ˜8%
- Recommended primary AC fuse: 500mA
- Weight: ˜1kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
- AS/NZS 61558.2.6 approval: Q042029
- AS3108 approval: CS/814/Q
|
|
Primary fitted with 200mm fly leads. Secondary taps have solder tags. |
|
M7115A ROHS
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 0.933A
- Sec. Series: 0.46A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 7VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜11%
- Weight: ˜265g
- PCB hole size: 1mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M7155 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 7VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 265g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 7.5 + 7.5
- Parallel : 0.933A
- Series: 0.46A
- Standard AS/NZS 61558.2.6 Certified
|
|
Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
|
M2155C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 15VA
- Insulation: Class E (120°C)
- Magnetising current: <60mA
- Temperature rise: <60°C
- Regulation: ˜10%
- Recommended primary AC fuse: 250mA
- Weight: ˜555g
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
|
|
Primary fitted with 200mm fly leads. Secondary taps have solder tags. |
|
M1150A |
|
- Power taps: 50, 100, 150, 200W
- Dimensions: 103 x 55mm
- Frequency response: 40Hz - 20kHz ±3dB
- Fly lead length: 200mm
- Efficiency: 90%
- Insertion loss: 0.8dB max.
|
|
These high power, high efficiency toroidal transformers are designed for matching 8 ohm speakers to 100V line amplifier systems. |
|
M2851C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 1.89VA
- Insulation: Class E (120°C)
- Magnetising current: <30mA
- Temperature rise: <65°C
- Regulation: ˜7.5%
- AC fuse: Not required (fitted internally)
- Weight: ˜145g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2853C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 6.3VA
- Insulation: Class E (120°C)
- Magnetising current: <45mA
- Temperature rise: <65°C
- Regulation: ˜13%
- Recommended AC fuse: 100mA
- Weight: ˜315g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2852C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 3.78VA
- Insulation: Class E (120°C)
- Magnetising current: <40mA
- Temperature rise: <65°C
- Regulation: ˜12%
- AC fuse: Not required (fitted internally)
- Weight: ˜235g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2854C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 3.6VA
- Insulation: Class E (120°C)
- Magnetising current: <40mA
- Temperature rise: <65°C
- Regulation: ˜12%
- AC fuse: Not required (fitted internally)
- Weight: ˜235g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 12V, 24 / Current : 150mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2152C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 12.5VA
- Insulation: Class E (120°C)
- Magnetising current: <45mA
- Temperature rise: <65°C
- Regulation: ˜11%
- Recommended AC fuse: 250mA
- Weight: ˜561g
- Primary connection: 200mm fly leads
- Secondary connection: 490mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage :12.5V / Current : 1A
|
|
Powertran EI-Core 240V AC mains transformer with 1A centre tapped secondary configuration. 6.25V and 12.5V secondary voltages available at 1A current output. Primary and secondaries fitted with 200mm flyleads. Fully electrical authority approved for AS/NZS 61558.2.6. |
|
M2170C NEW
|
|
- Primary Voltage: 240V AC
- Total VA Rating: 100VA
- Insulation: Class E (120°C)
- Magnetising Current: <85mA
- Temperature Rise: <70°C
- Regulation: ˜14%
- Recommended primary AC Fuse: 500mA
- Weight: ˜1.6kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
|
|
Powertran EI-Core 240V AC mains transformer with 6A dual multi tapped secondary configuration. Two sets of 0V, 12V and 15V secondaries are available at a maximum current of 6A (max current when secondaries connected in parallel) . Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for AS/NZS |
|
M2190C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 120VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ≈10%
- Recommended primary AC fuse: 500mA
- Weight: ≈1.4kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
|
|
Powertran EI-Core 240V AC mains transformer with 5A single tap secondary configuration. |
|
M4315A NEW
|
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 1.3A
- Sec. Series: 0.66A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |